  • IP Rating
  • IP66/67 with compatible gland
  • Operating Temperature
  • -40°C to +80°C
  • Components
  • Gland shroud only
  • Features
  • UV stable, acid and alkali resistant, flexible, easy to install
  • Usage
  • Used with cable glands to enhance ingress protection and prevent damage.
  • Product Type
  • Cable Gland Shroud
  • Application
  • For electrical and instrumentation cable terminations with MICC cable glands
  • Size
  • Available in various sizes to suit gland dimensions (e.g., 20mm, 25mm, 32mm, 40mm)
  • Dimension (L*W*H)
  • Depends on selected size (fits standard gland sizes)
  • Function
  • Provide sealing and mechanical protection for cable gland terminations.
  • Color
  • Transparent
  • Weight
  • Varies by size (approx. 10g to 50g)
  • Thickness
  • Approx. 1.5 mm to 3 mm (varies by model)
  • Environmental Protection
  • Protects against dirt, dust, liquid entry, and mechanical damage
  • Weather Resistance
  • Yes, suitable for outdoor use
  • RoHS Compliance
  • Yes
  • Compliance Standard
  • BS EN 60529
  • Material
  • PVC (Polyvinyl Chloride)
  • Flammability
  • Self-extinguishing
  • Suitable Cable Types
  • MICC and standard armoured/unarmoured cables
  • Service Life
  • Over 10 years under typical use
 
 

About MICC Gland Shrouds



Experience the elite durability and protection of MICC Gland Shrouds, top-rated, sought-after accessories for electrical installations. Fabricated in India using premium PVC, these peerless shrouds are engineered for astounding resilience, complying with BS EN 60529 and exceeding RoHS standards. Designed to safeguard MICC and standard armoured or unarmoured cables, they offer superior weather resistance, self-extinguishing properties, and a service life of over 10 years. Their transparent finish and varied sizes ensure a perfect fit, making them a must-have for outdoor and instrumentation applications. Get it now for unmatched cable safety!

Superior Protection and Versatile Usage

MICC Gland Shrouds are specifically developed for both general and specialized use in electrical and instrumentation cable terminations. Their primary competitive advantages include peerless flexibility, astounding weather resistance, and reliable sealing against dirt, dust, liquids, and mechanical damage. These shrouds are suitable for MICC as well as standard armoured and unarmoured cables. Enhance ingress protection and extend the longevity of your cable gland installations with these elite, top-quality shrouds.


Payment, Sample Policy and Packaging Details

For domestic markets, MICC Gland Shrouds are supplied under flexible payment terms, ensuring market value for customers across India. Transportation is handled with care, ensuring the product reaches you in pristine condition. Samples are available to allow evaluation before larger commitments, supporting informed decisions. Packaging details are tailored to suit order quantity and size, maintaining protection during transit and maximizing customer satisfaction in every shipment.


FAQ's of MICC Gland Shrouds:


Q: How do MICC Gland Shrouds enhance cable protection in outdoor environments?

A: MICC Gland Shrouds provide a robust seal against dirt, dust, liquid ingress, and mechanical damage, making them highly effective for outdoor use where cables are exposed to harsh weather and environmental factors.

Q: What types of cables are suitable for use with these shrouds?

A: These shrouds are designed for MICC cables as well as standard armoured and unarmoured cables, offering versatility for a broad range of electrical and instrumentation terminations.

Q: When should MICC Gland Shrouds be installed in a cable termination process?

A: Install these shrouds during the cable gland termination stage to ensure maximum ingress protection and mechanical safety before the final connection is made.

Q: Where can MICC Gland Shrouds be used?

A: They are suitable for installations in both indoor and outdoor environments, including industrial sites, instrumentation panels, and areas with high exposure to environmental contaminants.

Q: What is the process for selecting the right size of shroud for my application?

A: Select a shroud size that matches your cable gland dimensions-sizes typically include 20mm, 25mm, 32mm, and 40mm. Accurate sizing ensures proper sealing and optimal protection.

Q: What is the primary benefit of choosing these shrouds for your electrical projects?

A: The primary benefit is enhanced longevity and safety for cable gland connections, providing superior environmental protection and compliance with international standards.

Price 18 INR/ Piece

  • Minimum Order Quantity
  • 500 Pieces
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in MICC Accessories And Tools Category

MICC Clip

MICC Clip

Operating Temperature : 20C to 105C

Weight : Approximately 10g per clip

Product Type : Cable Clip

Color : Copper / Red Copper finish

Components : Copper clip, mounting hole

Function : Securely fastens and supports MICC cables

MICC Cable Cutting Tool

MICC Cable Cutting Tool

Operating Temperature : 10C to 50C

Weight : Approx. 0.8 kg

Product Type : Cable Cutting Tool

Color : Silver and black

Components : Hardened cutting blades, ergonomic handle

Function : Designed for precise cutting and trimming of mineral insulated copper clad (MICC) cables

Pot Wrench

Pot Wrench

Operating Temperature : 10C to 60C

Weight : Approximately 300500 grams

Product Type : Pot Wrench

Color : Silver

Components : Wrench handle, jaw, adjustment mechanism

Function : Used for tightening and loosening pots, plumbing, and utility pipework

MICC Red Gland Shroud

MICC Red Gland Shroud

Operating Temperature : 20C to +105C

Weight : Lightweight (typically a few grams depending on size)

Product Type : Gland Shroud

Color : Red

Components : Onepiece molded shroud

Function : Provides extra protection and insulation to the gland termination of mineral insulated (MI) cables